The intention of this wiki is to list the requirements for the monitoring agent as well as the requirements for the metrics and events that should be monitored or collected within the NFVI. In addition to the metrics/events collected about the NFVI, some information about the monitoring process (the process which collects the information and metrics) itself is also required.

This list should be developed in conjunction with the  Doctor (Faults) and VES Projects in OPNFV.

This wiki heavily references The ETSI NFV draft specification titled “Network Functions Virtualisation (NFV); Testing; NFVI Compute and Network Metrics Specification” which can be found here:  TST008 (please consult the latest version, and leave a comment if this link is broken, ETSI seems to move it frequently).

Monitoring Agent requirements:

Polling vs Event capture for the monitoring agent

 

In the context of the monitoring agent polling the subsystem it's querying. Both polling and event driven updates should be supported with events driven updates being the preferred model to use. This depends on the subsystem you are monitoring, default would be to leverage event based systems where they exist, but polling should be supported as a configuration option that can be selected by the end user.

In the context of the VIM polling the monitoring Agent:

  • Fault events should always use a push model, and the mechanism over which events are sent needs to be reliable.
  • Telemetry, can be polled or pushed (could be polled to spread the load on the collection side).
  • Network (over)load should be taken into consideration as regards which model to use (push  vs pull), you don't want to destabilize the network. push is more scalable overall and preferred for fault management.

 

Agent configuration

Should be able to dynamically:

  • Enable/disable/or restart resource monitoring
  • Get values/notifications
  • Get capabilities
  • Get the list of metrics being collected
  • flush the list of metrics
  • Set thresholds for resources
  • blacklist resources
  • support some sort of buffering mechanism, and should be able to configure
  • get the timing information for the agent and do aTiming sync if required.

 

Time stamping support

 

Events Requirements

Timing: 

Events must be detected within a 10ms interval in order to allow for a 40ms failover time.

Metrics/Events Format

It's important to define a common format that can be used for the list of identified metrics and events that should be monitored/collected in the NFVI.

  • + Name
  • + Where the Metric/Event is collected (e.g., the measurement point, such as Host/Guest/Both)
  • + Parameters (input factors or variables)
  • + Scope of measurement coverage
  • + Unit(s) of measure or associated severities
  • Definition
  • Method of Measurement
  • Sources of Error
  • Comments

In addition to the measurement result, items marked "+" should either be available for collection, or reported with the measurement result.

Distinction between metrics and events

For the purposes of Platform Service Assurance, it's important to distinguish between metrics and events as well as how they are measured (from a timing perspective).

A Metric is a (standard) definition of a quantity describing the performance and/or reliability of a monitored function, which has an intended utility and is carefully specified to convey the exact meaning of the measured value. A measured value of a metric is produced in an assessment of a monitored function according to a method of measurement. For example the number of dropped packets for a networking interface is a metric.

 

An Event is defined as an important state change in a monitored function.  The monitor system is notified that an event has occurred using a message with a standard format. The Event notification describes the significant aspects of the event, such as the name and ID of the monitored function, the type of event, and the time the event occurred. For example, an event notification would take place if the link status of a networking device on a compute node suddenly changes from up to down on a node hosting VNFs in an NFV deployment.

 

Information to be collected in conjunction with NFVI Metrics/Events

It's essential to collect some information about the environment that is being monitored as well as the monitoring process(es) themselves in order to associate the mertrics/events with the relevant host.

Host information:

Each host in a deployment should have a Unique identifier that distinguishes it from all other hosts. A UUID can be used in this case.

Monitoring Process information:

Each monitoring process in a deployment should have a Unique Process identifier.

Each monitoring process in a deployment should support the following events:

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments
 Heartbeat/ping Host/Guest (where the monitoring process is running)ping frequency and size of packet liveliness check N/A Heartbeat/ping to check liveliness of monitoring process external pingfalse alarm for host due to network interruption 

 

Each monitoring process in a deployment should support the following Metrics:

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments

write_queue/queue_length

 Host/Guest (where the monitoring process is running)measurement frequencyThe monitoring application being used The number of metrics currently in the write queue.    

write_dropped

 Host/Guest (where the monitoring process is running)measurement frequencyThe monitoring application being used The number of metrics dropped due to a queue length limitation.   

cache_size

 Host/Guest (where the monitoring process is running)measurement frequencyThe monitoring application being used The number of elements in the metric cache   
CPU utilization Host/Guest (where the monitoring process is running)measurement frequency, interrupt frequency, set of execution contexts, time of measurementThe CPUs that are being used by the monitoring applicationNanoseconds or percentage of total CPU utilizationThe CPU utilization of the monitoring processkernel interrupt to read current execution contextshort-lived contexts may come and go between interruptssee section 6 of TST008
Memory Utilization Host/Guest (where the monitoring process is running)Time of measurement, total memory available, swap space configuredThe Memory that is being used by the monitoring applicationKibibytesThe amount of physical RAM, in kibibytes, used by the monitoring applicationmemory management reports current values at time of measurement see section 8 of TST008

 

Timing Information

NFVI Other/Additional Information

BIOS information

NFVI Events

What about entire node and switch failures?  In terms of service affecting priority, host and switch failures are at the top as they can affect the most VMs / Containers / VNFs...

While the status of switches and hosts might be the domain of services that have a system-wide view, a host-resident component might be part of the monitoring functionality.

Compute

At a minimum the following events should be monitored:

  • Machine check exceptions (System, Processor, Memory...) [TODO: Break this down further]
    • DIMM corrected and uncorrected Errors

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments

MCEsHost Memory, CPU, IO Machine Check Exceptionusing mcelog  
PCIe ErrorsHost       


Networking

At a minimum the following events should be monitored for a Networking interface:

  • Link Status
  • Dropped Receive Packets – An increasing count could indicate the failure or service interruption of an upstream processes.  

vSwitch liveliness

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments
Link Status        
vSwitch Status (liveliness)        
Packet Processing Core Status        

 

Storage

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments
         

NFVI Metrics

Compute

At a minimum the following metrics should be collected:

  • CPU utilization TODO: Break this down further]
  • vCPU utilization TODO: Break this down further]
  • Memory utilization TODO: Break this down further]
  • vMemory utilization TODO: Break this down further]
  • Cache utilization
    • Hits
    • Misses
    • Instructions per clock (IPC)
    • Last level cache utilization
    • Memory Bandwidth utilization
  • Platform Metrics (thermals, fan-speed) [TODO: Break this down further]

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments
cpu_idleHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentageTime the host CPU spends idle  see CPU Utilization above, and section 6 of TST008
cpu_niceHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentageTime the host CPU spent running user space processes that have been niced. The priority level a user space process can be tweaked by adjusting its niceness.  see CPU Utilization above, and section 6 of TST008
cpu_interruptHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentageTime the CPU has spent servicing (hardware) interrupts.  see CPU Utilization above, and section 6 of TST008
cpu_softirqHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentageTime spent handling interrupts that are synthesized, and almost as important as Hardware interrupts (above). "In current kernels there are ten softirq vectors defined; two for tasklet processing, two for networking, two for the block layer, two for timers, and one each for the scheduler and read-copy-update processing. The kernel maintains a per-CPU bitmask indicating which softirqs need processing at any given time." [Ref]  see CPU Utilization above, and section 6 of TST008
cpu_stealHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentageCPU steal is a measure of the fraction of time that a machine is in a state of “involuntary wait.”  It is time for which the kernel cannot otherwise account in one of the traditional classifications like user, system, or idle.  It is time that went missing, from the perspective of the kernel.  see CPU Utilization above, and section 6 of TST008
cpu_systemHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentageTime that the CPU spent running the kernel.  see CPU Utilization above, and section 6 of TST008
cpu_userHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentage

Time CPU spends running un-niced user space processes.

 

  see CPU Utilization above, and section 6 of TST008
cpu_waitHost The host CPUs, individually or total usage summed across all CPUsnanoseconds or percentageThe time the CPU spends idle while waiting for an I/O operation to complete  see CPU Utilization above, and section 6 of TST008
total_vcpu_utilizationHost The host CPUs used by a guest, total usage summed across all CPUsnanoseconds or percentageThe total utilization summed across all execution contexts (except Idle) and all CPUs in Scope.  see CPU Utilization above, and section 6 of TST008

Networking

[TODO] Add a note on the vSwitch and add vSwitch specific metrics

At a minimum the following metrics should be collected for a Networking interface:

  • Total Packets received and transmitted
  • Total Octets (TX and RX)
  • Dropped packets (TX and RX)
  • Error frames (TX and RX) [TODO: Break this down further – just tried to do that...]
    • Frame Check Sequence Errors or CRC Errors
    • Runts (frames <64 octets in length)
    • Giants (frames >6000 octets in length)
  • Broadcast Packets (TX and RX)
  • Multicast Packets (TX and RX)

Other Metrics that should be collected for a Networking interface (if possible):

  • Average bitrate
  • Average latency

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments
Total Packets received       see section 7 of TST008
Total Packets transmitted       see section 7 of TST008
Total Octets received       see section 7 of TST008
Total Octets transmitted       see section 7 of TST008
Total Error frames received       see section 7 of TST008
Total Errors when attempting to transmit a frame       see section 7 of TST008
Broadcast Packets        
Multicast Packet        

Average bitrate

        
Average latency        

Storage

Disk Utilization

Name

Collection locationParameters

Scope of coverage

Unit(s) of measure

Definition

Method of Measurement

Sources of Error

Comments
        

 

The host CPUs, individually or total usage summed across all CPUs

  • No labels