Anuket Project

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 19 Next »


Introduction:

Cross-NUMA tests as part of OPNFV Plugfest (Gambia) - January 2019..............

  1. VSPERF-Scenarios: P2P and PVP.
  2. Workloads: vSwitchd, PMDs and VNF.
  3. VNF: L2 Forwarding
  4. vswitch: OVS and VPP.


Testbed:

 Intel POD12 

Node-4 (DUT), Node-5 (Software Traffic Generators) and Ixia H/W Traffic Generator.


CPU Topology on DUT

P2P Scenarios

Summary of PVP Scenarios:

Scenario

Possible Core-allocations:
Assumptions: Numa-0 (0-21) Numa-1 (22-43)

vSwitch Core #: 02

DUT Ports, TGen (Hardware) Ports

1

PMDs: 4, 5 (0x30)

DUT: eno5, eno6

TGEN: 5, 6

2

PMDs: 22, 23 (0xC00000)

DUT: eno5, eno6

TGEN: 5, 6

3

PMDs: 4, 22 (0x400010)

DUT: eno5, eno6

TGEN: 5, 6

4

PMDs: 4, 5 (0x30)

DUT: eno5, ens801f2

TGEN: 5, 7

5

PMDs: 22, 23 (0xC00000)

DUT: eno5, ens801f2

TGEN: 5, 7

6

PMDs: 4, 22 (0x400010)

DUT: eno5, ens801f2

TGEN: 5, 7

7

PMDs: 4, 5 (0x30)

DUT: ens801f2, ens802f3

TGEN: 7, 8

8

PMDs: 22, 23 (0xC00000)

DUT: ens801f2, ens802f3

TGEN: 7, 8

9

PMDs: 4, 22 (0x400010)

DUT: ens801f2, ens802f3

TGEN: 7, 8

PVP Scenarios

Summary of PVP Scenarios:

Scenario

Possible Core-allocations:

Assumptions: Numa-0 (0-21) Numa-1 (22-43)

vSwitch Core # : 02

DUT Ports

TGen Ports

(Hardware)

1

PMDs: 4, 5, 6, 7

(0xF0)

VNF: 8,9

DUT: eno5, eno6

TGEN: 5, 6

2

PMDs: 4, 5, 6, 7

(0xF0)

VNF: 22, 23

DUT: eno5, eno6

TGEN: 5, 6

3

PMDs: 4, 5, 6, 7

(0xF0)

VNF: 8, 22

DUT: eno5, eno6

TGEN: 5, 6

4

PMDs: 4,5,22,23

(0xC00030)

VNF: 8,9

DUT: eno5, ens801f2

TGEN: 5, 7

5

PMDs: 4,5, 22, 23

(0xC00030)

VNF: 24, 25

DUT: eno5, ens801f2

TGEN: 5, 7

6

PMDs: 4, 5, 22, 23

(0xC00030)

VNF: 8, 24

DUT: eno5, ens801f2

TGEN: 5, 7

7

PMDs: 22, 23, 24, 25

(0x3C00000)

VNF: 26, 27

DUT: ens801f2, ens802f3

TGEN: 7, 8

8

PMDs: 22, 23, 24, 24

(0x3C00000)

VNF: 4,5

DUT: ens801f2, ens802f3

TGEN: 7, 8

9

PMDs: 22, 23, 24, 25

(0x3C00000)

VNFs: 4,26

DUT: ens801f2, ens802f3

TGEN: 7, 8


Possible Variations

  1. Increase the Number of CPUs to 4 for the VNF.
  2. Phy2phy case (no VNF).
  3. Try different forwarding VNF
  4. Different Virtual Switch (VPP)
  5. RxQ Affinity.


Notes on Documentation

  1. must view log files, qemu threads need to match the intended scenario for VM -
  2. Christian created qemu command (and documentation) - check this for VM mapping
  3. SR: CT's command is only the host
  4. qemu command line -smp 2 should do this - simulates two Numa Nodes  - need to see how the VM see it's architecture: numactl -h
  • No labels